(5/11/2017) Day 20: Sinusoids and Phasors and Phasors: Passive RL Circuit Response

Day 20: Sinusoids







 Lab: Phasors - Passive RL Circuit Response

Prelab:

We first had to show that the amplitude gain and phase difference were as the lab packet had implied.
Then we found the cut off frequency Wc for the values of L = 1mH and R = 47 Ohms.




Procedure:

The circuit was pretty straightforward, so the fabrication stage of this lab was a breeze.


We then input the 3 frequencies required for analysis. Using the analog discovery, we displayed the v(in) - yellow, the v(L) - blue, and the i(in) - red by using the equation:


To measure the Gain we used:


and for the Phase difference we used:



Wc/10 = 4.7k


Wc = 47k


Wc*10 = 470k


Here are some tabulated results for the gain, and percent differences.


Summary: